10.4" gesture sensitive touchscreen with adjustable angle
Voltage
110-240 V
Good image quality is prime for a promising ultrasound. DC-70 Ultrasound System offers that and a lot more. Its unique touch gestures let you do more than you ever imagined, providing you with extremely easy and fast exams, enabling you to put patient care first.
Matching up with the requirements of our clients, we are involved in offering Biphasic Defibrillator. The Codemaster XL combines a DC defibrillator / cardioscope, annotated recorder and hands-off defibrillation capabilities into a single, high performance unit. It operates on AC power or internal battery supply and is also available with a noninvasive pacemaker. Designed for high-use areas of the hospital ,the high-speed Codemaster XL is perfect for operating rooms, intensive care units,cardiac care units and emergency departments. It changes from zero to 360 joules in under five seconds and offers a variety of advanced options so you can easily customize it to meet your facility’s needs.
Features:
Defibrillator with ECG and recorder
Provides 1-2-3 operation
Built-in pediatric paddles under slide-off adult paddles
Preset heart rate alarms
High-capacity battery
Built-in diagnostics
Battery:
Type: Rechargeable, sealed lead-acid battery. 4 Ah, 12 V nominal
Charge time: 2 hours to 90% of full capacity. 18 hours to 100% capacity Repeated charging to less than 100% will reduce the useful life of the battery
Capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording
Defibrillator:
Waveform: damped sinusoidal
Output energy (delivered): 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, and 360 joules
Charge control: push-button on apex paddle and on front panel
Charge time: less than 5 seconds to 360 joules with a functional battery installed
Charge-done indicator: display indicates available energy, charge-done light on apex paddle, charge done tone
Synchronizer: SYNC message appears on the monitor and is annoted periodically on the recorder while in synchronous mode
An audible beep sounds with each detected R-wave, while a marker on the monitor and sync mark on the recorder strip indicate the discharge point
Paddles: standard paddles are anterior/anterior
Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq)
Paddle cord is 10 feet (3m)
Full range of internal paddles available
Monitor:
Input: ECG activity may be viewed through the paddles or patient cable
Lead fault: LEADS OFF message and dashed baseline appear on the monitor if a lead becomes disconnected
Common mode rejection: Greater than 100 dB measured as per AAMI standards for cardiac monitors
Heart rate display: Digital read out on monitor from 20 to 280 bpm
Recorder:
Annotations: Time, date, heart rate, event markers, ECG mode, and selected energy
Recorder mode: Automatically documents events and ECG during defibrillation episodes
The recorder can be configured to run in either real time or with a 6-second delay
Frequency response: 0.5 to 40 Hz monitor bandwidth. 0.05 to 150 Hz diagnostic bandwidth is selectable